GVU Technical Report Number:
GIT-GVU-95-05
Title:
"Evaluation of the CyberGlove(TM) as a Whole Hand Input Device"
Authors:
G. Drew Kessler
Neff Walker
Larry F. Hodges
Abstract:
We present a careful evaluation of the sensor characteristics of the
CyberGlove(TM) model CG1801 whole hand input device. In particular,
we conducted an experimental study that investigated level of
sensitivity of the sensors, their performance in recognized angles,
and factors that affect accuracy of recognition of flexion
measurements. Among our results, we show that hand size differences
between the subjects of the study did not have a statisical affect on
the accuracy of the device. We also analyzed the effect of differect
software calibration approaches on accuracy of the sensors.
Keywords:
Hand input, input devices, CyberGlove(TM), device evaluation
You can access this technical report via:
PDF
Postscript
 
|